Special gasket
revoseal JG/JP
Encapsulated flat profile gasket: the internationally patented geometry of the raised outer and inner teeth completely encapsulates the graphite or PTFE layer. The tooth geometry is calculated so that ideal compression of the graphite and a double metallic seal are achieved even with low-grade bolts. revoseal JG and JP combine the advantages of metallic and soft-material sealing in an ideal way.
400 bar
Pressure from vacuum to 400 bar (Class 1500) · temperature −270 °C to +1000 °C, depending on the carrier material
Highlights
What sets JG/JP apart
Verifiable technical tightness
For apparatus flanges, the effective gasket width can be adapted for the qualified calculation of technical tightness according to TA Luft and VDI 2290 per DIN EN 1591-1.
Extreme operating ranges
Temperature: −270 °C to +1000 °C (depending on the carrier material). Pressure: from vacuum to 400 bar (Class 1500).
Lowest leakage rates
Lowest leakage rates of all gaskets available on the market. The JG/JP profiles build the tongue-and-groove principle into the gasket.
Tested and certified
Fire-safe certificate according to API 607 (also for PTFE) and blow-out resistance according to VDI 2200. Standard material 1.4571, total thickness 4.2 mm – other materials and thicknesses on request.
Versions
Types and cross sections
JG/JP-1
Encapsulated flat profile gasket for tongue & groove and male/female facings according to DIN EN 1514-4 TG and SR.
Download data sheet (PDF)
JG/JP-2
Encapsulated flat profile gasket with centring ring and predetermined breaking groove for flanges with smooth sealing face, form A and B according to DIN EN 1092-1, and for flanges according to ASME B16.5 / B16.47-A and B16.47-B. We recommend the JP version for pressures above 200 bar and temperatures above 500 °C.
Download data sheet (PDF)
JP Top
JP Top has the same properties as JG/JP-2, plus a secondary seal made of graphite or PTFE. This design is particularly suitable for cold lines where a corrosive medium forms in the atmosphere.
Download data sheet (PDF)
JG/JP-4
Encapsulated flat profile gasket with loose centring ring. Extends the JG/JP-2 principle: the loose centring ring prevents stresses in the component under high pressure and severe vibration. Suitable for up to 400 bar and 1,000 °C.
Download data sheet (PDF)
JP groove/flat
For the flange combination of form B and C.
JP double gasket
With bores for leakage sensors.
Dimensions
Dimension tables
Dimension table JG/JP according to DIN EN 1092-1
Encapsulated flat profile gasket with centring ring and predetermined breaking groove for flanges with smooth sealing face form A and flanges with sealing face form B according to DIN EN 1092-1.
DN = nominal size · total thickness 4.2 ± 0.1 mm · other thicknesses available · also available in other DIN and ASME dimensions · design and calculation according to revoseal factory standard · the graphite width required for a gasket calculation is available on request.
Dimension table JP-2 according to ASME B16.5
Encapsulated flat profile gasket JP-2 with centring ring and predetermined breaking groove for flanges according to ASME B16.5.
Inch = nominal size · total thickness 4.2 ± 0.1 mm · other thicknesses available · also available in other DIN and ASME dimensions · design and calculation according to revoseal factory standard · the graphite width required for a gasket calculation is available on request.
Dimension table JG-1
Encapsulated flat profile gasket for tongue & groove according to DIN 2512 and EN 1514-1 form TG.
DN = nominal size · total thickness 2.0 ± 0.1 mm · other thicknesses available · also available in other DIN and ASME dimensions · design and calculation according to revoseal factory standard · the graphite width required for a gasket calculation is available on request.
Apparatus & special gaskets
Custom-made to your specifications
Gasket solutions for apparatus and special flanges
For apparatus and special flanges, revoseal also manufactures high-quality gasket solutions to customer specifications with precise dimensions – for example gaskets for heat exchangers, pressure vessels, tank and filter systems, and for equipment and plants in the following sectors:
- Chemical and petrochemical industry
- Pipeline construction (oil and gas)
- Refineries
- Power plant construction
- Industrial plants
- Food and pharmaceutical industry
Due to their design, apparatus such as heat exchangers often have thin walls and weak flange geometries, which makes finding the optimal gasket a challenge. For apparatus flanges, the effective gasket width can be adapted for the qualified calculation of technical tightness according to TA Luft and VDI 2290 per DIN EN 1591-1. Gasket dimensions up to 4,000 mm are possible.
Looking for the right JG/JP gasket?
Tell us the flange type, nominal size and pressure rating – we will be happy to advise you and prepare a quotation.